Issues
As you go through Designer, there will be occasions where something has been configured incorrectly. These will be shown by the Issues icon . These issues, and more will also be shown when you Upload.
If any issues are found, the Issues tab will be opened automatically and a description of each issue will be listed so that you can take corrective action (or you can ignore and proceed if you like):
Issue - '?' will provide the specific details: | Solution |
---|---|
RIO A doesn't provide frequency band ? | Adjust the number of bands on the RIO A |
? doesn't support Analog Input | Change the Trigger or Controller/Remote Device type |
? doesn't support Digital Input | Change the Trigger or Controller/Remote Device type |
? doesn't support DMX Input | |
? doesn't support eDMX pass-through | Change the controller |
? doesn't support MIDI In | Change the device setting in the Midi Input trigger to a device with MIDI Input |
TPC has patch on DMX 1 but hasn't been configured with an EXT or a proxy LPC | Configure an EXT or DMX Proxy, or change the patch to eDMX |
? is not a TPC | Change the TPC triggers to match a TPC |
? is not found in the project | Add the remote device to the project |
? isn't configured to receive DMX Input | Configure the DMX input for the controller |
? must be configured as an Audio input device | Change the Mode of the RIO A to Audio |
? must be configured to have a held timeout for digital inputs | Set a held timeout in the controller interfaces |
? must be configured to have a repeat interval for digital inputs | Set a repeat interval in the controller interfaces |
? must be configured to have an EXT | Configure an EXT for the specified controller |
A content target hasn't been set | Select a content target for the action |
A group hasn't been set | Select a group for the action |
A location must be set in Project Properties for waypoint timelines to operate correctly | Set a location for the project |
A property hasn't been set | Set the properties for the action |
A scene hasn't been set | Select a scene for the action |
A timeline hasn't been set | Select a timeline for the action or condition |
All inputs on ? should be configured as either digital inputs or contact closures | Configure all inputs on the Controller or Remote Device |
Button number hasn't been set | Set a button number on the BPS button condition |
Content target transitions are only supported on VLC+ | Add a VLC+ to your project, or remove the action |
Controller doesn't have a MIDI Out port | Change the configured controller to a controller with a MIDI Output (LPC) |
Controller has configured serial port 2 but the associated device only has one serial port | Change the serial port number in the serial input and/or output to 1 |
Controller has live video programming but the associated device hasn't been upgraded to support video capture | Remove the Live Video preset, or add a LPC X with video capture card or a VLC |
Controller has no fixtures patched to it | Patch one or more fixtures to the controller |
Controller is configured to receive DMX Input but the associated device doesn't support DMX Input | Change the DMX input to an eDMX source |
Controller is configured with an EXT but the associated device has no attached EXT |
Connect the TPC to an EXT, ensure EXT is in v2 or uncheck the Configure EXT box |
Controller is not a TPC | Change the controller associated with the TPC actions to a TPC |
Controller is outputting KiNET so you must ensure that the protocol network interface is on the same network as the patched power supplies | Configure the Network 2 (Protocol) settings to the same network as the KiNet power supplies |
Controller isn't associated with a device | Associate the controller with an attached device. |
Device number is not set | Set a remote device number |
Device type is not set | Set a remote device type |
Digital Word is not supported on ? | Change the remote device type |
eDMX pass-through for universe ? requires a controller with at least ? DMX ports | |
eDMX pass-through requires TPC to be configured with an EXT | Configure the TPC with an EXT |
A trigger hasn't been set | Select a trigger in the Enqueue Trigger action |
Ethernet bus ? uses port ? which clashes with the internal web server and will prevent correct operation | Change the HTTP port or the ethernet bus port |
Input ? must be configured as a digital input or contact closure | Change the input to a Digital or Contact Closure |
Input ? must be configured as an analog input | Change the input to Analog |
Input ? of ? must be configured as a digital input or contact closure | Change the input on the remote device to a Digital or Contact Closure |
Input ? of ? must be configured as an analog input | Change the input on the remote device to Analog |
Input number hasn't been set | Set an Input number on the trigger/condition |
Interface font is not found | Choose a different font for the interface |
Location hasn't been set in Project Properties | Set a location in the project properties |
No colours have been enabled | Select at least one colour in the Set RGB action/s |
No DALI interface is selected | Select a DALI interface |
The remote device associated with ? cannot report incorrect DALI power | Interfaces associated with a RIO D4 cannot detect incorrect DALI power |
No DMX port is selected |
Select a DMX port in the eDMX pass through action |
No error has been selected to check | Select an error in the DALI ballast error |
No group has been set to release | Select a group in the Release All action |
No interface has been chosen | Add an interface to the TPC |
No page has been assigned | Select a page in the Set TPC Page action |
No script has been assigned | Select a Script in the Run Script Action |
No targets have been set to release | Configure the Release All action |
Not set to match any data | Set the input string for the trigger |
Not set to send any data | Set the string to output |
Note On with zero velocity will never match | Reconfigure the MIDI input |
Power supply has an invalid IP address | Set a valid IP address for the KiNET Power Supply |
Source is not set | Set the Bus for the Ethernet Input |
Source media is not found | Replace the source media |
The associated device is missing its memory card | Replace the memory card |
The associated device is not online | Reassociate the controller, or reconnect the controller |
The associated device is on the wrong network | Change the network settings of the controller or computer |
The associated device is running the wrong firmware | Reload firmware |
The associated device's memory card is corrupt | Replace the controller's memory card |
The associated device's memory card is read-only | Unlock the memory card |
The chosen audio bus doesn't have band ? |
Increase the number of audio buses on the RIO A |
The chosen audio bus has no input assigned to it | Change the audio bus, or link a RIO A to the audio bus |
The chosen timecode bus has no input assigned to it | Change the timecode bus, or link a timecode source to the timecode bus |
The same variable is used to select the BPS number and the button number | Change the variable number to use for the BPS or button |
The same variable is used to select the IP address and the port | Change the variable numbers to use for the IP address or port |
The same variable is used to select the slot name and set the slot value | Change the variable numbers to use for the slot name and slot value |
The script has no source | Check the source of the script |
The script has not compiled | Check the source of the script for errors |
The serial port of ? is set to DMX Out | Change the Serial port to a serial protocol, or choose a different port |
The serial port of ? must be set to DMX Input | Change the Serial port to DMX input, or choose a different port |
The serial port of ? must be set to RS232 or RS485 | Change the Serial port |
The slot name has not been set | Set a slot name for the Set Text Slot action |
There is only 1 serial port on ? | Change the serial port number to 1 |